Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
An Official Journal of the Japan Primary Care Association ; : 335-339, 2015.
Article in Japanese | WPRIM | ID: wpr-377238

ABSTRACT

<b>Purpose</b> : This preliminary study was aimed to investigate potentially beneficial changes in prescription of antibiotics by use of Gram staining in an otorhinolaryngology outpatient clinic.<br><b>Methods</b> : This study was done in a single clinic. Changes in the type and amount of antibiotics prescribed, in addition to the clinical outcomes prior to and following introduction of Gram staining, were analyzed retrospectively.<br><b>Results</b> : Following introduction of Gram staining in 2005, the costs for antibiotics per person per year decreased to about one-fifth. The number of prescriptions per 100 patients decreased from 20.9 in 2006 to 3.6 in 2012 for macrolides, from 7.9 in 2005 to 2.4 in 2012 for third-generation cephalosporins, and increased from 1.6 in 2004 to 3.9 in 2012 for penicillins. In addition, for every 50 pediatric cases of acute sinusitis, the number of patients to whom no antibiotics were prescribed increased 9-fold and the number of patients to whom 2 or more types of antibiotics were prescribed decreased from 26 to 9 cases, while the mean period in days until resolution was shortened by 6 days.<br><b>Conclusion</b> : The results of this pilot study suggest that the use of Gram staining for diagnosis and prescription of antibiotics in an otorhinolaryngology outpatient clinic may lead to significantly improved antibiotic prescription practices. Further study through proper controlled studies are felt to be neceesary.

2.
Journal of Pharmaceutical Analysis ; (6): 156-159, 2012.
Article in Chinese | WPRIM | ID: wpr-472103

ABSTRACT

Horseradish peroxidase (HRP) is generally used as a label enzyme in enzyme immunoassay (EIA).The procedure used for HRP detection in EIA is critical for sensitivity and precision.This paper describes a novel fluorimetric assay for horseradish peroxidase (HRP) using sesamol as substrate.The principle of the assay is as follow:sesamol (3,4-methylenedioxy phenol) is reacted enzymatically in the presence of hydrogen peroxide to produce dimeric sesamol.The dimer is fluorescent and can be detected sensitively at ex.347 nm,em.427 nm.The measurable range of HRP was 1.0 × 10-18 to 1.0 × 10-15 mol/assay,with a detection limit of 1.0 × 10-18 tmol/assay.The coefficient of variation (CV,n=8) was examined at each point on the standard curve,with a mean CV percentage of 3.8%.This assay system was applied to thyroid stimulating hormone (TSH) EIA using HRP as the label enzyme.

SELECTION OF CITATIONS
SEARCH DETAIL